- Temporary Portable Power Distribution
- >
- CEP Temporary Portable Power Boxes
- >
- CEP Temporary Power Boxes
- >
- CEP 20-50A 125/250V Mini Centers
- >
- Southwire/ CEP 6522UGMX 20A 125/250V 8 OUTLET 20A UG GFCI MINI BOX
Southwire/ CEP 6522UGMX 20A 125/250V 8 OUTLET 20A UG GFCI MINI BOX
SKU:
6502GU/ 6522UGMX
$438.34
$341.91
$341.91
On Sale
Unavailable
per item
**CEP is now Southwire**
Southwire/ CEP’s Portable Power Distribution Mini-Centers have been engineered utilizing the latest in GFCI technology, providing the user with the highest level of electrical safety. These compact power boxes are designed to plug into the 4–wire full power outlet on small generators. By utilizing this outlet, the user maximizes the output of his unit while also provided with 2 separate 20 amp 125V GFCI protected circuits. Each circuit has its own breaker and GFCI device offering for outlets per circuit. These units are available with either 20 amp 125/250V or 30 amp 125/250V input plugs. Check your generator for the proper device.
- Input – 20A 125/250V (L14-20P)
- Output -4 – 20A 125/250V (5-20R) Duplex
- 6′ 10/4 SOW cord w/ male plug
Additional Information
Weight 14.00 lbs Dimensions 21 x 14.5 x 11 in AMPS 20 Amps Volts 125/250V GFCI Yes Power Inlet 20A 125V L14-20P Male Plug Receptacles 4ea. 5-20R Duplex Outlet Description 20A Mini U-Ground Outlet Type U-Ground Feed-Through No 3R Rated No Construction Powder Coated Steel Dimensions (In.) 10.25 X 10 X 8.5 HxWxD |
Product Documents
|
CEP’s Portable Power Distribution Mini-Centers have been engineered utilizing the latest in GFCI technology, providing the user with the highest level of electrical safety. These compact power boxes are designed to plug into the 4–wire full power outlet on small generators. By utilizing this outlet, the user maximizes the output of his unit while also provided with 2 separate 20 amp 125V GFCI protected circuits. Each circuit has its own breaker and GFCI device offering for outlets per circuit. These units are available with either 20 amp 125/250V or 30 amp 125/250V input plugs. Check your generator for the proper device.
These GFCI modules give the user not only ground fault protection, but also open neutral and reverse phasing protection. They are listed to U.L. 1640 Standards for Portable Power Distribution and designed to stand up to the toughest of jobsite conditions. Each unit has been carefully assembled to provide the ultimate in electrical safety as well as meeting current OSHA standards. Now helps you comply with the New NEC 2017 Rule for Portable Generators up to 15kw, which requires GFCI protection on the 125/250V outlet.
These GFCI modules give the user not only ground fault protection, but also open neutral and reverse phasing protection. They are listed to U.L. 1640 Standards for Portable Power Distribution and designed to stand up to the toughest of jobsite conditions. Each unit has been carefully assembled to provide the ultimate in electrical safety as well as meeting current OSHA standards. Now helps you comply with the New NEC 2017 Rule for Portable Generators up to 15kw, which requires GFCI protection on the 125/250V outlet.