Thermal Care SQ2A14 Air-Cooled Portable Chiller 13.1 Tons
SKU:
SQ2A14
$0.00
Unavailable
per item
The SQ Series portable chillers are for indoor use in industrial manufacturing locations. The chillers are produced in our ISO 9001:2008 certified facility. Chillers with a water-cooled or integral air-cooled condenser ship with a full refrigerant charge. Units with a remote air-cooled condenser ship with a nitrogen charge. All units are in a heavy gauge
powder coated steel cabinet with tools-free access.
Specifications:
Cooling Tons 13.1
Set Point Range (°F) 20-80
Fan Air Flow (cfm)Â 10,000
Standard Pump HP 1 1/2 GPM 31 PSI 36
Unit MCA @ 460/3/60(amps)Â 41
Ship Weight (lbs)Â 1215
Tons based on 50°F leaving water, 95°F ambient air entering the condenser, R407c refrigerant, and operating at sea level.Â
MCA is Minimum Circuit Ampacity (for wire sizing).
**** CALL FOR SPECIAL PRICING****
powder coated steel cabinet with tools-free access.
Specifications:
Cooling Tons 13.1
Set Point Range (°F) 20-80
Fan Air Flow (cfm)Â 10,000
Standard Pump HP 1 1/2 GPM 31 PSI 36
Unit MCA @ 460/3/60(amps)Â 41
Ship Weight (lbs)Â 1215
Tons based on 50°F leaving water, 95°F ambient air entering the condenser, R407c refrigerant, and operating at sea level.Â
MCA is Minimum Circuit Ampacity (for wire sizing).
**** CALL FOR SPECIAL PRICING****
Click here for Features & Brochure:
- Energy efficient and reliable rotary compressor (1 ton unit) or scroll compressor (2 and 3 ton units)
- Electronic hot gas bypass for capacity control
- Stainless steel brazed plate evaporator for corrosion protection
- (Air-Cooled Chillers) Chillers with integral air-cooled condensers include include air inlet filters and copper tube/aluminum finned air-cooled
condensers. - (Water-Cooled Chillers) Generously sized water-cooled condenser for industrial environments.
- (Remote Condensers) Galvanized steel fan section and coil baffles, copper tube/aluminum fin coils, and direct drive multi-blade propeller fans with venture orifices to optimize efficiency
- (Water-Cooled Units) Condenser water regulating valve to provide constant head pressure
- Refrigerant TXV, filter/drier, and sight glass
- Freeze stat safety switch to protect the evaporator from damage due to freezing in the chiller
- Encapsulated high and low refrigerant pressure safeties
- Nonferrous water circuit construction
- Insulated polyethylene reservoir with removable cover
- Stainless steel process pump with pressure gauge
- Fail safe pressure or flow switch interlocked with compressor
- Y-strainer to protect evaporator from contamination
- Internal valved bypass line to protect pump and evaporator
- Integral air-cooled and water-cooled condenser units tested under full load prior to shipment